When 2^−ΔΔCt is valid
Each cycle doubles the product at 100 % efficiency, so a difference of one cycle is a factor of two. Livak and Schmittgen’s method assumes both the target and reference amplify with near-100 % and equal efficiency, which should be checked with a dilution series. If the efficiencies differ, Pfaffl’s model raises each efficiency (1 + E) to its own ΔCt and gives an unbiased ratio. Use the mean Ct of technical replicates for each value.
Assumptions and limits
- Reference gene expression does not change with the treatment.
- Ct values are means of technical replicates within the linear range of the assay.
- Efficiencies come from standard curves (see the PCR copy number calculator).
References
- Livak, K. J. and Schmittgen, T. D. (2001), Analysis of relative gene expression data using real-time quantitative PCR and the 2^−ΔΔCT method, Methods 25(4), 402–408.
- Pfaffl, M. W. (2001), A new mathematical model for relative quantification in real-time RT-PCR, Nucleic Acids Research 29(9), e45.
Questions
- What fold change do these Ct values give: target 25 and reference 18 treated, target 27 and reference 18.5 control?
- ΔΔCt = −1.5, so expression is 2.828 times higher in the treated sample (log₂ fold change 1.5).
- How much does a 95 % target efficiency change the answer?
- With the Pfaffl method and a 100 % reference, the ratio falls to 2.689 instead of 2.828.