Most Probable Number (MPN) Calculator

The most probable number method estimates bacterial concentration from how many tubes in a dilution series show growth, and is widely used for coliforms in water and food. This calculator solves the MPN by maximum likelihood for any number of tubes and any sample volumes, so you are not limited to a printed table.

Inputs

Results

MPN per 100 mL
79.24
MPN per mL
0.7924
Approximate lower 95 % limit per 100 mL
26
Approximate upper 95 % limit per 100 mL
242
Tube code
5-3-0

    RefBIO-MIC-002
    MethodMaximum likelihood: Σ pᵢvᵢ/(1 − e^(−λvᵢ)) = Σ nᵢvᵢ
    UnitsSI
    Date2026-11-24

    Working

    Calculated in SI base units; inputs are converted from the units you choose.

    1. Likelihood equation for the density λ (per mL)Σ pᵢvᵢ/(1 − e^(−λvᵢ)) = Σ nᵢvᵢtubes 5-3-0 with 10, 1, 0.1 mL; Σnᵢvᵢ = 55.5 mL
    2. Solve numericallybisection on λλ = 0.7924 per mL = 79.24 per 100 mL
    3. Approximate confidence intervalSE(ln λ) = 1/(λ√I), I = Σ nᵢvᵢ²e^(−λvᵢ)/(1 − e^(−λvᵢ))SE(ln λ) = 0.5687 → 25.99 to 241.6 per 100 mL

    Why MPN is a likelihood estimate

    A tube stays negative only if it received no organisms, which for a Poisson distribution happens with probability e^(−λv). Combining all tubes, the density λ that makes the observed pattern most likely satisfies Σpᵢvᵢ/(1 − e^(−λvᵢ)) = Σnᵢvᵢ, which the calculator solves numerically. Published MPN tables are built from the same equation, so the results agree with them; the confidence limits here use a normal approximation on the log scale and differ slightly from tabulated limits.

    Assumptions and limits

    • Organisms randomly (Poisson) distributed in the sample.
    • Any tube that receives at least one organism shows growth.
    • Three dilutions with the same number of tubes at each.

    References

    • Cochran, W. G. (1950), Estimation of bacterial densities by means of the “most probable number”, Biometrics 6(2), 105–116.
    • US FDA Bacteriological Analytical Manual, Appendix 2: Most Probable Number from Serial Dilutions (Blodgett, R.).

    Questions

    What is the MPN for a 5-tube test with 10, 1 and 0.1 mL and the result 5-3-0?
    79.24 per 100 mL, matching the 79 given in standard MPN tables.
    What does 3-1-0 give in a 3-tube test with 0.1, 0.01 and 0.001 mL?
    42.73 per mL, close to the tabulated 43.