Choosing the extinction coefficient
Each protein has its own extinction coefficient, set by its tryptophan, tyrosine and cystine content. Compute it from the sequence with the protein molecular weight calculator, or use published values: about 1.37 for a 1 mg/mL IgG solution and 0.66 for bovine serum albumin. Using the generic assumption that A280 = 1.0 means 1 mg/mL can be wrong by a factor of two or more.
Assumptions and limits
- Blank-subtracted absorbance within the linear range (about 0.1 to 1.5).
- No nucleic acid contamination, which also absorbs at 280 nm (check A260/A280 below about 0.6).
- Native-state extinction coefficient; denaturing conditions shift it slightly.
References
- Pace, C. N., Vajdos, F., Fee, L., Grimsley, G. and Gray, T. (1995), How to measure and predict the molar absorption coefficient of a protein, Protein Science 4, 2411–2423.
- Gill, S. C. and von Hippel, P. H. (1989), Calculation of protein extinction coefficients from amino acid sequence data, Analytical Biochemistry 182, 319–326.
Questions
- What is the concentration of BSA with A280 = 0.65?
- 0.9853 mg/mL (14.83 µM), using ε = 43,824 M⁻¹cm⁻¹ and 66,430 Da.
- How do I use an IgG absorbance of 1.37 per mg/mL?
- Choose the 1 mg/mL option: an A280 of 0.65 then means 0.4745 mg/mL.
This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.