Choosing interference
ISO 286 fits such as H7/p6 (light press) and H7/s6 (heavy drive) set the interference range. Check the joint at the minimum interference for torque and at the maximum for hub stress.
Assumptions and limits
- Solid shaft and hub of the same material; plane stress, elastic.
- Smooth surfaces; no centrifugal or thermal operating effects.
References
- Shigley's Mechanical Engineering Design, section 3-16: press and shrink fits.
- DIN 7190, Interference fits: calculation and design rules.
- ISO 286-2, ISO code system for tolerances.
Questions
- What pressure does a 40 µm interference on a 50 mm steel shaft give?
- About 60 MPa with a 100 mm hub, transmitting about 2.1 kN·m over a 60 mm length at μ = 0.15.
- How hot should I heat the hub?
- Enough to open the bore by the interference plus a working clearance: about 150 °C above ambient for this example. Stay below the tempering temperature of the hub.
This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.