Interference (Press and Shrink) Fit Calculator

Pressing or shrinking a hub onto a slightly larger shaft creates a joint that transmits torque by friction, with no keys. This calculator uses thick-cylinder (Lamé) theory to give the contact pressure, hub stress, torque capacity, press force, and the temperature to heat the hub for shrink fitting.

Inputs

Results

Contact pressure
60
Hub hoop stress at the bore
100
Transmissible torque
2,121
Press-in force
84.82
Hub temperature rise for shrink fitting
150
  • Compare hub hoop stress with the hub material yield strength, and check that the surfaces are finished as assumed; roughness reduces effective interference.

RefENG-MEC-008
Methodp = E·δ·(D_o² − d²)/(2d·D_o²) (same material, solid shaft); T = μpπd²L/2; F = μpπdL
UnitsSI
Date2026-11-23

Working

Calculated in SI base units; inputs are converted from the units you choose.

  1. Contact pressure (Lamé)p = Eδ(D_o² − d²)/(2dD_o²)p = 60 MPa
  2. Hub hoop stressσ = p(D_o² + d²)/(D_o² − d²)σ = 100 MPa
  3. Torque and press forceT = μpπd²L/2; F = μpπdLT = 2,121 N·m, F = 84.82 kN
  4. Shrink temperatureΔT = (δ + clearance)/(α·d)ΔT = 150 K

Choosing interference

ISO 286 fits such as H7/p6 (light press) and H7/s6 (heavy drive) set the interference range. Check the joint at the minimum interference for torque and at the maximum for hub stress.

Assumptions and limits

  • Solid shaft and hub of the same material; plane stress, elastic.
  • Smooth surfaces; no centrifugal or thermal operating effects.

References

  • Shigley's Mechanical Engineering Design, section 3-16: press and shrink fits.
  • DIN 7190, Interference fits: calculation and design rules.
  • ISO 286-2, ISO code system for tolerances.

Questions

What pressure does a 40 µm interference on a 50 mm steel shaft give?
About 60 MPa with a 100 mm hub, transmitting about 2.1 kN·m over a 60 mm length at μ = 0.15.
How hot should I heat the hub?
Enough to open the bore by the interference plus a working clearance: about 150 °C above ambient for this example. Stay below the tempering temperature of the hub.

This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.